Does a tankless heater work during a Riverside power outage?
A gas tankless unit still has gas when the lights go out, but it can't light without electricity. Here's what to expect and what to do.
When the power goes out in Riverside, most gas tankless water heaters stop making hot water. The gas is still there, but the controls, igniter and fan run on electricity, and the Department of Energy notes that tankless controls don't work during an outage. Electric tankless units stop as well. Whatever hot water is already in the pipes comes out first, then the taps run cold until power returns. Check Riverside Public Utilities' outage map, report the outage if your area isn't shown, and bring appliances back one at a time once power is restored. A battery backup can keep a gas unit going if it's sized for the heater.
Why a gas unit needs electricity
A tankless heater only lights when water starts moving through it. A flow sensor tells the control board, the board starts the combustion fan and sparks the igniter, then it trims the flame to hold your set temperature. Every one of those steps runs on household current. The Department of Energy's Building America guide says the electric controls of a tankless water heater are not operational during a power outage. No power means no flame, even with a full gas supply.
The DOE tankless page also tells shoppers to look for an intermittent ignition device rather than a standing pilot light, because a pilot burns gas all day for nothing. That efficient design is part of why these heaters rely on the grid.
What you'll notice when the lights go out
- The display on the unit goes blank.
- Opening a hot tap brings no fan sound and no click of ignition.
- Hot water sitting in the pipes runs warm for a short while, then turns cold.
- An electric tankless unit behaves the same way, since its heating elements need power.
Leaving a hot tap open won't hurt the heater. It simply won't fire. Close the tap so you don't waste water waiting.
Confirm it's an outage, then report it
Before you blame the heater, make sure the power really is out. Riverside Public Utilities' outage page has a live outage map. If your street isn't on it, RPU's unplanned outage page says to check your circuit breaker first. A tripped breaker can cut the heater's outlet while the rest of the house stays lit, which looks a lot like a broken unit.
If the breaker isn't the cause, RPU takes outage reports online through a 311 service request during business hours and lists a phone line for water and power emergencies at any hour. For a major or life threatening emergency, RPU says to call 911.
Staying safe while you wait
RPU's outage safety tips cover the basics. Keep the fridge and freezer closed. Disconnect appliances and electronics so a surge doesn't damage them. Don't use a gas stove for heat. Run a backup generator only outdoors and away from windows. Ready.gov explains why that last one matters so much: carbon monoxide is colorless and odorless, and it can kill people and pets.
The garage where many tankless units hang doesn't count as outdoors. And if you smell gas at any point, leave the house and call SoCalGas or 911 from outside, as SoCalGas advises.
When the power comes back
The California Public Utilities Commission suggests unplugging electric appliances during an outage to avoid overloaded circuits and fire hazards when power returns, then turning them back on one at a time. A tankless unit on a plug fits that routine. One wired straight to a circuit can be switched off and on at its breaker instead.
Once power is back, open a hot tap and see whether the unit fires and the display reads normally. If it shows a code or the water stays cold, write down the code and the model number, follow the manual's reset step only if it lists one, and check the error codes guide. Don't keep resetting a unit that keeps faulting.
Keeping hot water through an outage
Battery backup
The DOE guide says that keeping a tankless heater running without grid power takes an uninterruptible power supply, a battery backup, with enough capacity for the heater's electrical needs. For a gas unit that load is mainly the controls and the fan. Check the electrical rating on the unit's label and anything the manual says about backup power, then have the plumber or an electrician confirm the setup.
A home generator
A generator can run a gas tankless unit too. The CPUC says a licensed electrician should install a home generator, and RPU notes that it doesn't provide backup generation itself. If someone in the house relies on powered medical equipment, RPU points customers to its Utilicare Program.
Electric tankless units
Backup gets much harder with an electric whole house unit. The Building America guide puts most of them on a 208 or 240 volt supply, pulling anywhere from 50 to 200 amps. A small battery pack won't carry that. If outages weigh on your decision, factor that into the choice of fuel.
Or stay with a tank
Some households keep a tank partly for this reason. The tankless vs tank comparison covers the trade-off, and the conversion page explains what changes if you do switch. An outage doesn't change how much gas a tankless burner needs once it's running, which the gas line guide covers.
Planning ahead when the unit goes in
- Ask whether the unit plugs into an outlet or is wired to a circuit, since that shapes your backup options.
- Leave space near the heater if you may add a battery backup later.
- Keep the manual, the model number and the reset steps somewhere you can find in the dark.
- Keep a flashlight in the garage near the heater and the breaker panel.
Call (951) 376-3972 if you're planning an install and want backup power talked through on the quote, or if your unit won't come back after an outage. The plumber calls back, looks at the setup and gives you the price before any work starts.
Talk it through with the plumber
Call (951) 376-3972 or request a callback.
You hear the options and the price before work starts.
Questions people ask
Why does a gas tankless water heater need electricity?
A gas tankless unit uses electricity for its control board, flow sensor, igniter and combustion fan, which together light and regulate the burner each time hot water is drawn. The Department of Energy notes these controls don't work during a power outage, so the gas supply alone can't make hot water.
Can a tankless water heater run on a battery backup?
A battery backup can keep a gas tankless unit running, and the Department of Energy says it needs enough capacity for the heater's electrical needs. Check the electrical rating on the unit's label and in the manual, and have the plumber or an electrician confirm the setup. Electric whole house units draw far too much for small backups.
How do I report a power outage to Riverside Public Utilities?
Check RPU's live outage map first, and if your area isn't shown, check your circuit breaker. When the breaker isn't the cause, RPU takes reports online through a 311 service request during business hours and lists a phone line for power and water emergencies at any hour. For a life threatening emergency, call 911.
Is it safe to power a tankless heater with a generator?
A generator can power a gas tankless unit if it runs only outdoors and away from windows, as RPU and Ready.gov advise, because carbon monoxide is colorless and odorless. The CPUC says a licensed electrician should install a home generator. A garage, even with the big door open, isn't outdoors.
Will a tankless water heater come back on after the power returns?
Whether it restarts on its own depends on the model and on whether anything faulted, so open a hot tap once power is back and see whether the unit fires and the display reads normally. If it shows a code or the water stays cold, note the code and the model number, follow the manual's reset step only if it lists one, then call for a diagnosis.
Should I unplug my tankless water heater during an outage?
Unplugging is a sensible step for a unit on a plug, since the CPUC suggests unplugging electric appliances during an outage to avoid overloads and fire hazards when power returns. Turn things back on one at a time afterward. A unit wired straight to a circuit can be switched off at its breaker instead.
Can a power outage damage a tankless water heater?
An outage by itself usually just stops the unit until power returns. The bigger concern is a surge when power comes back, which is why RPU suggests disconnecting appliances and electronics during an outage. If the heater acts up afterward, note any code and have it checked rather than resetting it again and again.